ISY-99i/ISY-26 INSTEON:Linking a Motion Sensor

From Universal Devices, Inc. Wiki
Revision as of 11:36, 26 September 2010 by Rand (Talk | contribs)

Jump to: navigation, search

Motion Sensor Linking

The Insteon Motion Sensor cannot be linked using Auto Discover.

  • Menu - Link Management/New INSTEON device
  • Enter the address.
    • The Motion Sensor address is on a sticker inside the battery compartment.
  • Select the Motion Sensor [10.01] from the drop down list. It's the 2nd from last device, at the time of this writing.
Select Motion Sensor from the list
  • Click Ok.
  • Press and Hold the Set button for 5 seconds to put the Motion Sensor in linking mode as per the requester.
Press and Hold the Set button for 5 seconds
  • Click OK.
  • Wait while the ISY initializes communications with the Motion Sensor.
  • The Motion Sensor will create three new nodes in the ISY:
  1. Motion Sensor-Sensor: Will switch to On when Motion is detected and switch to Off after no motion + timeout.
  2. Motion Sensor-Dusk/Dawn: On when the light on the sensor falls below the threshold.
  3. Motion Sensor-Low Bat: Sends an On when the battery voltage falls below a specific level.
  • Any of these can be used as a Condition in a program.


Motion Sensor Options

Motion Sensor Options
  • Timeout (minutes) - Defines the period of inactivity before the Motion Sensor will send an Off. Default = 1 minute. Range = 0.5 - 120 minutes in 30 second increments.
  • LED Brightness - Default = 100. Range is 0 - 255.
  • Darkness Sensitivity - The higher the value, the darker it needs to be for the unit to see night. Default = 35. Range = 0 - 255.
Motion Sensor v.2 must have the jumper set on pin 5 to use the software settings.


Motion Sensor FAQs

  • To access the Motion Sensor, one or more Access Points must be installed.
    • Tip: Plug an Access Point into the PLM for positive results.
  • After a new battery is inserted or a factory reset is performed the motion sensor needs 5 minutes to stabilize the circuitry.
  • The Set button toggles between Motion Off and On.
  • The Motion Sensor must be “awake” to hear messages.
    • Tip: Put the Motion Sensor into linking mode to keep it awake for 4 minutes.
    • The Motion Sensor can be taken out of linking mode by pressing the Set button twice.
  • A command is only sent when there is a change.
    • Do not expect to see a status for Motion until there has been a change.
    • Do not expect to see a status for Dawn/Dusk until there has been a change.
    • Do not expect to see a status for the battery until the battery becomes depleted.
  • Dusk/Dawn requires a change to persist for 3.5 minutes before transmitting a command.
    • Dusk (dark) is represented by On.
  • When the On-Only Mode jumper is set the motion sensor will send an On when there is new activity only after there is no activity for the duration of the timeout period plus ~ 2-4 seconds.
    • This is the same behavior as when the motion sensor sends an Off.
  • To clear the status of the Low Battery sensor after it is initiated you have to replace your battery and then issue a Query on the low bat node in the Admin Console.


Motion Sensor Trick

To activate the MotionSensor for reads and writes without pressing the Set button:

  • If you have a helper you can use the On command.
  • If you are alone you will probably have to key with the Off command.
  1. Select the Motion Sensor from the device tree.
  2. Open the ISY dialogue concerning the MS Options.
  3. The Communications Mode dialogue will open asking you to put the MS in linking mode.
  4. Active the MS with motion.
  5. Immediately after seeing the state change (this could be to On or Off) click the Ok on the Communications Mode requester.
  6. ISY will read the options from the MS.
  7. By the time you change any options the MS will be sleeping again.
  8. If the MS is still On wait for it to change to Off. Otherwise activate the MS again.
  9. Immediately after seeing the state change (this could be to On or Off) click the OK in the Options Settings requester.
  10. ISY will write the changes to the MS.
  11. If you miss the window you will see Request Failed and have to start over.