Difference between revisions of "ISY-99i/ISY-26 INSTEON:Linking an IRLinc Transmitter"

From Universal Devices, Inc. Wiki
Jump to: navigation, search
(Linking an IRLinc Transmitter)
Line 1: Line 1:
 
=Linking an IRLinc Transmitter=
 
=Linking an IRLinc Transmitter=
 +
ISY firmware 2.7.7
  
# Factory reset 2411T
+
# Factory reset the 2411T
 
# Put ISY in linking mode ('Start Linking')
 
# Put ISY in linking mode ('Start Linking')
 
# Double click the set button on the 2411T
 
# Double click the set button on the 2411T

Revision as of 15:27, 16 January 2010

Linking an IRLinc Transmitter

ISY firmware 2.7.7

  1. Factory reset the 2411T
  2. Put ISY in linking mode ('Start Linking')
  3. Double click the set button on the 2411T
  4. Press the remote control button to be learned, aiming it at the base of the 2411T, you should hear a beep
  5. Press and hold the set button on the 2411T for about 3 seconds, it will beep and will link it to the PLM (and ISY). You won't see the node in the tree.
  6. Wait for a second beep from the 2411T indicating link is complete. This beep happen about 3-5 seconds after the beep in step 5.
  7. Repeat steps 3-6 to add additional buttons.
  8. Click 'Finish' on the ISY linking popup
  9. You should start seeing nodes appear in the tree, one for each button you linked.


  • IRLinc TX does not follow batch processing. This is not a bug.




ISY-26 INSTEON / ISY-99i Series INSTEON : How-To Guide

ISY-99i/ISY-26 INSTEON:Link Management Menu