User:BitSmith: Difference between revisions

From Universal Devices, Inc. Wiki
Jump to navigation Jump to search
(Home Automation in Southern California)
No edit summary
Line 2: Line 2:
'''UDI (at) AndrewSite (dot) com'''
'''UDI (at) AndrewSite (dot) com'''


I like to leave the whole-house fan on for a while.  How to make a countdown timer (my first article);
 
*I like to leave the whole-house fan on for a while.  How to make a countdown timer (my first article);
http://wiki.universal-devices.com/index.php?title=Countdown_Timer
http://wiki.universal-devices.com/index.php?title=Countdown_Timer


I want to ensure everything is off after a power failure.  How to set preferences after power failure;
 
*I want to ensure everything is off after a power failure.  How to set preferences after power failure;
http://wiki.universal-devices.com/index.php?title=Power_Failure
http://wiki.universal-devices.com/index.php?title=Power_Failure


Answering a question by CPRail1, here's how to make a motion controlled security light that can be kept on;
 
*Answering a question by CPRail1, here's how to make a motion controlled security light that can be kept on;
http://wiki.universal-devices.com/index.php?title=Motion_Sensor_(Security_light)_with_latch
http://wiki.universal-devices.com/index.php?title=Motion_Sensor_(Security_light)_with_latch




And I'm enjoying and learning on the Forum;
*I'm finding that the IoLinc 2450 does not always show proper relay condition if using Momentary settings.  I will put a proper post shortly, but in the meantime;
Until IoLinc wrong response bug is fixed, here is a workaround.
 
When using IoLinc in Momentary mode, include this program;
'''Relay Workaround'''
If
    Control  'Garage Relay' is not switched Off
    Or Status 'Garage Relay' is not Off
Then
    Wait 1 second
    Set 'Garage Relay' Off
 
 
 
*And I'm enjoying and learning on the Forum;
http://forum.universal-devices.com/memberlist.php?mode=viewprofile&u=5223
http://forum.universal-devices.com/memberlist.php?mode=viewprofile&u=5223


Cheers...
Cheers...

Revision as of 18:42, 14 March 2014

Feel free to contact me; UDI (at) AndrewSite (dot) com


  • I like to leave the whole-house fan on for a while. How to make a countdown timer (my first article);

http://wiki.universal-devices.com/index.php?title=Countdown_Timer


  • I want to ensure everything is off after a power failure. How to set preferences after power failure;

http://wiki.universal-devices.com/index.php?title=Power_Failure


  • Answering a question by CPRail1, here's how to make a motion controlled security light that can be kept on;

http://wiki.universal-devices.com/index.php?title=Motion_Sensor_(Security_light)_with_latch


  • I'm finding that the IoLinc 2450 does not always show proper relay condition if using Momentary settings. I will put a proper post shortly, but in the meantime;

Until IoLinc wrong response bug is fixed, here is a workaround.

When using IoLinc in Momentary mode, include this program; Relay Workaround

If
   Control   'Garage Relay' is not switched Off
   Or Status 'Garage Relay' is not Off
Then
   Wait 1 second
   Set 'Garage Relay' Off


  • And I'm enjoying and learning on the Forum;

http://forum.universal-devices.com/memberlist.php?mode=viewprofile&u=5223

Cheers...