ISY-99i/ISY-26 INSTEON:Linking a MorningLinc

From Universal Devices, Inc. Wiki

==MorningLinc Linking==

ISY firmware 2.8.2+

  1. Manually link the MorningLinc to the Locks(s)
  2. See Link Management Menu to tell the ISY to Start Linking.
  3. Select the third option 'Add devices found in links and keep existing links'.
    • If you select 'Remove existing links' it removes all links from the MorningLinc and due to the security measures on the MorningLinc the PLM can no longer send commands to it.
  4. Link the MorningLinc to the ISY by pressing the Set button on the MorningLinc for 3-5 seconds.
    • If the MorningLinc does not appear on the ISY console press the set button once again and press and hold again.
  5. Click on the Finish button on the Linking in Progress dialogue requester.
  6. Some dialogue will take place between the ISY and the MorningLinc to create the links necessary to view and control the device state.
  7. The MorningLinc should now be available as a device in the Console and in Programs.


2458A1_Manual



ISY-26 INSTEON / ISY-99i Series INSTEON : How-To Guide

ISY-99i/ISY-26 INSTEON:Link Management Menu